Milwaukee multiparameter bench instrument mod. MW180 MAX 5 IN 1

pH-ORP-EC-TDS-NaCl-Temp

The Milwaukee MW180 5-in-1 MAX pH / ORP / EC / TDS / NaCl / Temp is preferred by people who test samples in various applications.

The easy-to-use logging function enables data collection without notes and messy errors. From aquaculture, the environment, research to educators, the MI180 MAX is your affordable meter for fast and accurate readings.

This tool offers:


PRECISION
People choose MW180 5-in-1 MAX pH / ORP / EC / TDS / NaCl / Temp to improve the accuracy and efficiency of their testing program.
With easy 1-point EC / NaCl calibration and up to 3 pH points, 7 stored standard pH buffer choices, 6 stored EC calibration solutions 2-point temperature calibration, the meter can be quickly calibrated with higher temperature accuracy than other meters and provides more accurate temperature compensation readings than a one-point calibration.

The MW180 5-in-1 MAX benchtop meter has an accuracy of ± 1% of reading for EC / TDS and NaCL.
The instrument is supplied with conductivity probe MA814DB / 1 (4 rings), laboratory pH electrode MA917B / 1 and temperature sensor MA831R , which allow the instrument to automatically adjust the reading of pH / ORP / EC / TDS / NaCl for the effect of temperature (ATC).
The instrument can also be used as a very accurate thermometer with an accuracy of +/- 0.4 ° C (+/- 0.8 ° F)

ROBUSTNESS
The sturdy meter is built to withstand shocks and has a sleek design that includes a small bench footprint.

LOW MAINTENANCE
MW180 MAX pH / ORP / EC / TDS / NaCl / Temp comes with the combined Milwaukee MA814DB / 1 EC sensor and MA917B / 1 pH electrode.
Designed to be low maintenance and able to withstand the most demanding samples.
MA814DB / 1 and MA917B / 1 are ideal for use in horticulture, aquaculture, environmental laboratories, water treatment / conditioning and many other applications.

FEATURES OF THE PROJECT
Quick and easy to read results with a large duel-level digital LCD display.
Extreme accuracy down to +/- 0.002 pH and 1% of reading for EC / TDS / NaCl | +/- 0.4 ° C (+/- 0.8 ° F).
Extended ranges for pH / ORP / EC / TDS / NaCl.
Lightweight and elegant design with a small counter footprint.
Simple and easy-to-use RS232 / USB (opto-isolated) recording and download functions.
GLP data, date and time.
Access on demand or automatic. up to 50 records per parameter.
Simple measurement: simply place the probe (s) in the sample, mix gently and wait for the reading to stabilize.
Automatic pH calibration up to 3 points, simple single point factor calibration for EC / TDS / NaCl and two points for temperature allowing for greater accuracy.
Robust, low maintenance, high performance and easy to clean pH / EC / TDS / NaCl / Temp probes.
Integrated temperature sensor.
12VDC power supply (included).
Automatic or manual temperature compensation.
Internal clock date to keep track of different time-dependent functions (calibration, timestamp, calibration timeout).
3-foot probe cables for greater flexibility when testing.
Includes MA9315 electrode holder, pipettes, initial calibration solutions, software and all cables.

CARE, USE AND CLEANING
PH / EC / TDS meters usually start to malfunction due to problems with sediment on the conductivity probe rings or building up on the glass pH bulb. Dirt on the EC probe rings or ph bulb can change the impedance.
Cleaning the rings is simple.
Slide the plastic screen and clean with deionized water and a soft cloth to keep the readings accurate.
For pH, simply dip the pH electrode into the MA9016 cleaning solution.

STORAGE
When not in use, store the meter and EC probe in a safe area to avoid damage.
The EC probe is stored dry.
The pH probe should be stored wet with MA9015 Storage Solution to keep the bulb moist during periods of non-use for best performance and durability.

CALIBRATION
Easy 1-point EC / TDS / NaCl calibration for ease of use, up to 3-point pH calibration and two-point temperature calibration for maximum accuracy in (ATC).
Regular calibration is best to keep your MI180 5-in-1 MAX benchtop meter accurate for all of your readings.

 PH range: -2.00 to 16.00 pH / -2,000 to 16,000 pH
MV range: ± 699.9mV / ± 2000mV
EC range: 0.00 to 29.99 uS / cm / 30.0 to 299.9 uS / cm
CE range: 300 to 2999 uS / cm
EC range: 3.00 to 29.99mS / cm / 30.0 to 200.0mS / cm
EC range: up to 500.0 mS / cm (uncompensated EC) *
TDS range: 0.00 to 14.99 ppm (mg / L)
TDS range: 15.0 to 149.9 ppm (mg / L) / 150 to 1499 ppm (mg / L)
TDS range: 1.50 to 14.99 ppt (g / L) / 15.0 to 100.0 ppt (g / L)
TDS range: up to 400 g / L (uncompensated TDS) * (with factor 0.80)
NaCl range: 0.0 to 400.0%
Temp. Range: -20.0 to 120.00 ° C (-4.0 to 248.0 ° F)
PH resolution: 0.01 pH / 0.001 pH
MV resolution: 0.1mV / 1mV
CE resolution: 0.01 uS / cm / 0.1 uS / cm / 1 uS / cm
CE Resolution: 0.01mS / cm / 0.1mS / cm
TDS resolution: 0.01 ppm (mg / L) / 0.1 ppm (mg / L) / 1 ppm (mg / L)
TDS resolution: 0.01 ppt (g / L) / 0.1 ppt (g / L)
NaCl resolution: 0.1%
Temperature Resolution: 0.1 ° C / (0.1 ° F)
Accuracy @ 20 ° C / 68 ° F
pH: ± 0.01 / ± 0.002 pH
mV: ± 0.2mV / ± 1mV
EC: ± 1% of reading / ± 0.05 uS / cm or 1 digit, whichever is greater
TDS: ± 1% of reading / ± 0.03 ppm or 1 digit, whichever is greater
NaCl: ± 1% of reading
Temperature: ± 0.4 ° C (± 0.8 ° F)
Relay mV offset: ± 2000 mV
PH calibration: 1, 2 or 3 calibration points, with 7 stored buffers: 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45
EC / TDS: 1-point slope calibration, 6 standards: 84 uS / cm, 1413 uS / cm, 5.00 mS / cm, 12.88 mS / cm, 80.0 mS / cm, 111.8 mS / cm / 1 point offset calibration: 0.00 uS / cm
NaCl: 1 point, with MA9050 salinity calibration solution
Temperature: 2 points, 0 and 50 ° C (32 and 122 ° F)
Temperature compensation: automatic or manual from -20.0 to 120.0 ° C (-4.0 to 248.0 ° F)
Conductivity temperature coefficient: selectable from 0.00 to 6.00% / ° C (EC and TDS only)
TDS factor: 0.40 to 0.80 / Default value: 0.50
PH probe: MA917B / 1 (included)
Temperature probe: MA831R (included)
EC probe: MA814DB / 1 (4 rings, included)
On-demand recording: maximum 50 samples for each range: (pH, mV / Rel mV, EC, TDS, NaCl)
PC connectivity: RS232 / USB optoisolated
Power supply: 12 VDC adapter (included)
Dimensions: 230 x 160 x 95mm (9.0 x 6.3 x 3.7 inches)
Environment: 0 to 50 ° C / 32 to 122 ° F; max RH 95%
Weight: 0.9kg / 2.00lb.
Warranty: 3 years on the meter

* Uncompensated conductivity (TDS) is the value of conductivity (or TDS) without temperature compensation.

CONTACTS


ENRICO BRUNO s.r.l.
Via Duino 140
10127 Torino Italy
Tel. +39 011 3160808
Fax +39 011 3160753
PEC pec@pec.enrico-bruno.it
CF/P.IVA: 04891320014

WRITE TO US


For orders, prices requests and offers, technical service commerciale@enrico-bruno.it
For administration service amministrazione@enrico-bruno.it
For Direction – Purchase Department acquisti@enrico-bruno.it

FOLLOW US


Facebook Twitter Blogger